FRP Properties
Typical Physical Properties for .090'' Contractor Grade |
||||
---|---|---|---|---|
Property | Test Method | Unit | Glasteel Class C General Purpose Result | Glasteel Class A Fire Retardant Result |
Flexural Strength | ASTM D-790 | PSI | 17,000 | 10,000 |
Flexural Modulus | ASTM D-790 | PSI | 6.0 X 105 | 3.1 X 105 |
Tensile Strength | ASTM D-638 | PSI | 8,000 | 7,000 |
Tensile Modulus | ASTM D-638 | PSI | 9.43 X 105 | 3.1 X 105 |
% Elongation | ASTM D-638 | % | 1.20 | 1.80 |
Water absorption 21 C @ 72 hrs | ASTM D-570 | % | 0.17 | 0.72 |
Izod Impact Strength | ASTM D-256 | ft. -lbs. /in. | 7.0 | 7.16 |
Coef. of Linear thermal Expansion | ASTM D-696 | in./in. /F | 2.22 X 10-5 | 2.39 X 10-5 |
Barcol Hardness | ASTM D-2583 | Avg. | 30 | 35 |
Specific Gravity | ASTM D-792 | N/A | 1.6138 | 1.5743 |
Abrasion Resistance | TABER | % WT Loss | 1.6138 | 1.5743 |
Flash Ignition Temp. | ASTM 1929 | C | 430 | 400 |
Self Ignition Temp. | ASTM 1929 | C | 450 | 430 |
Flame Spread. | ASTM E-84 | N/A | less equal 200 | less equal 25 |
Smoke Generation | ASTM E-84 | N/A | less 450 | less 450 |